Why the record matters
A signed delivery note proves the box arrived. It does not prove the box was cold. Food safety systems based on HACCP treat temperature during transport as something to monitor and keep records of, so when an auditor, a customer or an inspector asks whether the cold chain held, the temperature record is the answer.
What it should include
- Who and where: the customer, pickup and delivery addresses, and the vehicle.
- The required range: for example −3 to +5°C for chiller cargo or −25 to −18°C for frozen.
- What was recorded: minimum, maximum and average temperature from a logger travelling with the cargo, ideally with a graph over time.
- Time in transit: when the cargo was loaded and when it was delivered.
- Excursions: any time the temperature left the range, when it happened, how long it lasted and where the vehicle was.
- Proof of delivery: who signed, when, and anything noted at the door.
How to read it
Start with the verdict: did the recorded temperature stay inside the required range for the whole journey? If there was an excursion, look at how far out it went and for how long. A brief rise while a door was open is different from a long period out of range, and the record should let you tell which it was.
A good record states problems plainly. An excursion that is reported with the delivery is far more useful than one discovered later by the customer.
What Frimas records
Every Frimas job comes with proof of delivery and a temperature record showing the required range and the time in transit. Recorded temperatures and any excursions are added wherever the vehicle's logger is connected, and the record never smooths over a problem: if the temperature left the range, it says when and for how long. Records stay in your account, so an audit later is a search, not an argument.